Get complete information related to latest Economizer Tube Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Economizer Tube Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Economizer Tube Tenders.
Tender For carrying out rectification works of ss gratings in economizer, ltr & lts zones and providing of ss sleeves for economizertubes at front and rear gratings to avoid tube rubbing of units-3&4 boilers during annual overhaul period for the year 2026-27.
Tender For corrigendum : overhaul works on boiler pressure parts for replacement of eroded tubes of ltsh, back-pass and economizertubes and metal filling on eroded tubes where ever required after d-meter survey, inspection, fixing and adjustment of erosion protection shields at unit-6/stage-iv/dr.mvr rtpp during annual overhaul period 2026-27.
Tender For corrigendum : supply of steam water analysis system main spares and e and c c c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , conductivity analyzer -online retractable type , sample handling system for main steam superheated , sample handling system for main steam saturated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for condensate cep outlet inlet cooling wtr , sample handling system for dm water , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 6 mandays at manufacture works and 6 mandays at site , mandatory spares as per tech specs , supervision of e and c services charges at site , supervision of e and c visit charges
Tender For corrigendum : supply of water wall tube, od 63.5 x 5.6 mm, sa 210 gr- c , tube od 76.1mm x 7.1mm, sa 210 gr c , tube, od 54 x 4.5 mm, sa 213 t-11 , tube, od 44.5 x 4.5mm, sa 213 t-11, gr-c, ltsh upper bank , ltsh tube 44.5 x 4.5mm, sa 210 gr-c , economizertube 31.8 x 4.5mm, sa 210 gr -a , tube, od 44.5 x 5 mm, sa 210 gr-a1 , scw offset bends left side corner bends , scw offset bends right side corner bend , 180 degree u bend for economizer od 31.8 x 4.5mm , supply tube hit-1 d63.5x5.6 , supply tube hit-2 d63.5x5.6 , u clamp for ltsh hanger tube , 90 degree bend 63x5.6 mm , 90 degree bend for fin welded panel scr1 to scr16, 63.5 x 5.2 mm sa210 gr-c , water wall bot 90 degree bend 63.5 x 5.2mm, sa210 gr-c , scallop bar for ltsh terminal tubes , fin flat 12.7x6, 2.5 to 3m is2062e250a , fin flat 76x6, l2.5m to 3m is2062e250a , fin 90x6, 2.5 to 3m is2062e250a
Tender For corrigendum : supply of water wall tube, od 63.5 x 5.6 mm, sa 210 gr- c , tube od 76.1mm x 7.1mm, sa 210 gr c , economizertube 31.8 x 4.5mm, sa 210 gr -a , fin flat 12.7x6, 2.5 to 3m is2062e250a , economizer straight shield with double clamp 31.8 x 3.15 x1500 mm , tube od 44.5 x 4.5mm, sa 213 t-11, ltsh tube , tube, od 54 x 4.5 mm, sa 213 t-11, platen sh tube , w.w plain tube 44.5 x 4.5mm, sa 210 gr- c
Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For providing of facility management services - lumpsum based - industrial; cleaning of boiler economizertubes; consumables to be provided by service provider (inclusive in contract cost)
Tender For tender for straight heat shield with two nos. clamps for water wall tube dia. 63.5mm , straight heat shield with clamps for ltsh straight for tube dia. 44.5mm , heat shield with clamps for water wall screen straight tube for tube dia. 76.1mm , heat shield with clamps for s.h. screen and hanger tubes of dia. 51mm , straight heat shield with clamps for economizertubes of dia. 32mm , straight heat shield with two nos. clamps for sh and rh tube dia 48 mm , ss rod 10mm
Tender For corrigendum : supply of spares of soot blowers of (2x600 mw), katpp, rvunl, jhalawar - "lance tube assembly with flange, nozzel and nozzel head pipe.soot blower location: plsh area (ik-1/2/3/4) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: plsh area (ik-5/6/7/8/9/10) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipesoot blower location: fsh (ik-11/12/13/14/15/16), frh (ik-17/18/19/20/21/22),prh(ik-23/24), ltsh(ik-25/26) area in u#1& 2 respectively ", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: prh(ik-27/28/29/30, ltsh area(ik-31/32/33/34/35/36)in u#1& 2 respectively", "poppet valve assembly for all lrsbsoot blower location: plsh/fsh/frh/prh/ltsh area", "poppet valve assembly for hrsbsoot blower location: economizer area", "screw tube (lance tube) with packing assembly for fsbsoot blower location: water wall area", "feed tube with flange for fsbsoot blower location: water wall area", "goose neck valve assembly for fsbsoot blower location: water wall area", "lance tube with multi -jet element nozzel assembly for aphsbsoot blower location: air pre-heater area"